AT / DE / EN / IT / FR / ES / PL

Decentralized ventilation units for individual apartments System PICHLER

Die neue Größe im Wohnbau: LG 150

Product description compact units LG 150 - LG 500P, PHI-certified

The passive house-certified compact ventilation units are used for controlled aeration and ventilation. Developed and produced at the Klagenfurt site. The compact ventilation units LG 150 - LG 450 can also be flexibly controlled via PICHLER App. In order to improve the room comfort, they can be combined with the active air humidification unit LBE.


LG 150, PHI-certified

Standard version A:
Living spaces from 40 m² to 120 m² 
Airflow: 30 to 150 m³/h

Version B:
Living spaces from 40 m² to 160 m²
Airflow: 30 to approx. 200 m³/h

LG 350/450, PHI-certified

Living spaces from approx. 100 m² to approx. 350 m²
Airflow: 50 to 350 m³/h / 450 m³/h


LG 500 P with PI-HMI,PHI-certified

Living spaces from 150 m² to 400 m²
Airflow: 150 to 550 m³/h
Control unit: 3.5" colour touch screen PI-HMI
Networking: Possibilities of cross-linking or connection to a higher-level building automation system

  • Integrated web server
  • Modbus RTU
  • Modbus TCP/IP
  • BACnet
  • LON

 

» Brochure PICHLER-Domestic Ventilation For Family Homes
» Videos: Filter change & control with control unit MINI

 

EN 779/ISO 16890 - filter class selection:

» Guidelines ISO 16890
» Filter selection EN 779/ISO 16890

App




Eco-design

Lables in accordance with EU Regulation 1253/1254-2014

Addition to the specific energy consumption, LG 150-500P

LG 150 A/AF - specific energy consumption:

• A+ is applicable when controlled in accordance with local requirements

• A is applicable with manual control, time control or centralized requirements control

Maximum airflow: 150 m3/h

The rated energy efficiency class is valid up to the specified maximum airflow.

Sound power level LWA in interior spaces: 39 dB(A)

 

LG 150 B - specific energy consumption:

• A is applicable with manual control, time control or centralized requirements control

• A+ is applicable when controlled in accordance with local requirements

LG 150 BF - specific energy consumption:

• B is applicable with manual control or time control

• A is applicable with centralized requirements control or when controlled
in accordance with local requirements

Maximum airflow: 180 m3/h

The rated energy efficiency class is valid up to the specified maximum airflow.

Sound power level LWA in interior spaces: 45 dB(A)

 

LG 350 - specific energy consumption:

• A+ is applicable with centralized requirements control or when controlled
in accordance with local requirements

• A is applicable with manual control or time control

LG 350 F - specific energy consumption:

• A+ is applicable when controlled in accordance with local requirements

• A is applicable with manual control, time control or centralized requirements control

Maximum airflow: 350 m3/h

The rated energy efficiency class is valid up to the specified maximum airflow.

Sound power level LWA in interior spaces: 38 dB(A)

 

LG 450 - specific energy consumption:

• A+ is applicable when controlled in accordance with local requirements

• A is applicable with manual control, time control or centralized requirements control

LG 450 F - specific energy consumption:

• A is applicable with manual control, time control, centralized requirements control
or when controlled in accordance with local requirements

Maximum airflow: 450 m3/h

The rated energy efficiency class is valid up to the specified maximum airflow.

Sound power level LWA in interior spaces: 43 dB(A)

 

LG 500 / 500 P - specific energy consumption:

• A+ is applicable when controlled in accordance with local requirements

• A is applicable with manual control, time control or centralized requirements control

LG 500 F / 500 PF - specific energy consumption:

• A is applicable with time control, centralized requirements control or when controlled
in accordance with local requirements

• B is applicable with manual control

Maximum airflow: 445 m3/h

The rated energy efficiency class is valid up to the specified maximum airflow.

Sound power level LWA in interior spaces: 42 dB(A)