Decentralized ventilation units for individual apartments System PICHLER

Product description compact units LG 150 - LG 500P, PHI-certified
The passive house-certified compact ventilation units are used for controlled aeration and ventilation. Developed and produced at the Klagenfurt site. The compact ventilation units LG 150 - LG 450 can also be flexibly controlled via PICHLER App. In order to improve the room comfort, they can be combined with the active air humidification unit LBE.
LG 150, PHI-certified
Standard version A:
Living spaces from 40 m² to 120 m²
Airflow: 30 to 150 m³/h
Version B:
Living spaces from 40 m² to 160 m²
Airflow: 30 to approx. 200 m³/h
LG 350/450, PHI-certified
Living spaces from approx. 100 m² to approx. 350 m²
Airflow: 50 to 350 m³/h / 450 m³/h
LG 500 P with PI-HMI,PHI-certified
Living spaces from 150 m² to 400 m²
Airflow: 150 to 550 m³/h
Control unit: 3.5" colour touch screen PI-HMI
Networking: Possibilities of cross-linking or connection to a higher-level building automation system
- Integrated web server
- Modbus RTU
- Modbus TCP/IP
- BACnet
- LON
» Brochure PICHLER-Domestic Ventilation For Family Homes
» Videos: Filter change & control with control unit MINI
EN 779/ISO 16890 - filter class selection:
App
Operating and installation instructions
08LG150_OperatingInstallationInstruction_V2020.07.pdf (3.6 MB)
08LG250A_OperatingInstallationInstruction_V2020.07.pdf (3.6 MB)
08LG350_450_OperatingInstallationInstruction_V2022.04.pdf (5.0 MB)
08LG500P_OperatingInstallationInstruction_V2020.08.pdf (3.0 MB)
08External control extension for external water registers_V2022.05.pdf (381.6 kB)
08External control extension with PI-SYS-OPT_V2020.09.pdf (1.1 MB)
08External control extension with pressure sensors_V2017.12.pdf (452.3 kB)
Eco-design
Product fiche (EU Regulation 1253/1254-2014)
Product fiche Pichler_LG 150 AF.pdf (1.0 MB)
Product fiche_Pichler LG 150 A.pdf (148.6 kB)
Product fiche Pichler_LG 150 BF.pdf (1.1 MB)
Product fiche_Pichler LG 150 B.pdf (149.4 kB)
Product fiche_Pichler LG 350.pdf (223.0 kB)
Product fiche_Pichler LG 350 F.pdf (223.1 kB)
Product fiche_Pichler LG 450.pdf (221.8 kB)
Product fiche_Pichler LG 450 F.pdf (222.7 kB)
Product fiche_Pichler LG 500_with_KomfortG.pdf (191.5 kB)
Product fiche_Pichler LG 500 F_with_KomfortG.pdf (190.7 kB)
Product fiche_Pichler LG 500 P_with_PI_HMI.pdf (194.9 kB)
Product fiche_Pichler LG 500 PF_with_PI_HMI.pdf (194.9 kB)
Lables in accordance with EU Regulation 1253/1254-2014
Addition to the specific energy consumption, LG 150-500P
LG 150 A/AF - specific energy consumption:
• A+ is applicable when controlled in accordance with local requirements
• A is applicable with manual control, time control or centralized requirements control
Maximum airflow: 150 m3/h
The rated energy efficiency class is valid up to the specified maximum airflow.
Sound power level LWA in interior spaces: 39 dB(A)
LG 150 B - specific energy consumption:
• A is applicable with manual control, time control or centralized requirements control
• A+ is applicable when controlled in accordance with local requirements
LG 150 BF - specific energy consumption:
• B is applicable with manual control or time control
• A is applicable with centralized requirements control or when controlled
in accordance with local requirements
Maximum airflow: 180 m3/h
The rated energy efficiency class is valid up to the specified maximum airflow.
Sound power level LWA in interior spaces: 45 dB(A)
LG 350 - specific energy consumption:
• A+ is applicable with centralized requirements control or when controlled
in accordance with local requirements
• A is applicable with manual control or time control
LG 350 F - specific energy consumption:
• A+ is applicable when controlled in accordance with local requirements
• A is applicable with manual control, time control or centralized requirements control
Maximum airflow: 350 m3/h
The rated energy efficiency class is valid up to the specified maximum airflow.
Sound power level LWA in interior spaces: 38 dB(A)
LG 450 - specific energy consumption:
• A+ is applicable when controlled in accordance with local requirements
• A is applicable with manual control, time control or centralized requirements control
LG 450 F - specific energy consumption:
• A is applicable with manual control, time control, centralized requirements control
or when controlled in accordance with local requirements
Maximum airflow: 450 m3/h
The rated energy efficiency class is valid up to the specified maximum airflow.
Sound power level LWA in interior spaces: 43 dB(A)
LG 500 / 500 P - specific energy consumption:
• A+ is applicable when controlled in accordance with local requirements
• A is applicable with manual control, time control or centralized requirements control
LG 500 F / 500 PF - specific energy consumption:
• A is applicable with time control, centralized requirements control or when controlled
in accordance with local requirements
• B is applicable with manual control
Maximum airflow: 445 m3/h
The rated energy efficiency class is valid up to the specified maximum airflow.
Sound power level LWA in interior spaces: 42 dB(A)
Etikett_Pichler_LG_150_A_A+.pdf (400.1 kB)
Etikett_Pichler_LG_150_A_A.pdf (400.0 kB)
Etikett_Pichler_LG_150_AF_A+.pdf (400.1 kB)
Etikett_Pichler_LG_150_AF_A.pdf (400.0 kB)
Etikett_Pichler_LG_150_B_A+.pdf (371.7 kB)
Etikett_Pichler_LG_150_B_A.PDF (356.1 kB)
Etikett_Pichler_LG_150_BF_A.PDF (356.1 kB)
Etikett_Pichler_LG_150_BF_B.PDF (356.1 kB)
Etikett_Pichler_LG_350_A+.pdf (461.0 kB)
Etikett_Pichler_LG_350_A.pdf (461.0 kB)
Etikett_Pichler_LG_350_F_A+.pdf (461.1 kB)
Etikett_Pichler_LG_350_F_A.pdf (461.0 kB)
Etikett_Pichler_LG_450_A+.pdf (460.7 kB)
Etikett_Pichler_LG_450_A.pdf (460.7 kB)
Etikett_Pichler_LG_450_F_A.pdf (460.7 kB)
Etikett_Pichler_LG_500_A+.pdf (371.0 kB)
Etikett_Pichler_LG_500_A.pdf (370.9 kB)
Etikett_Pichler_LG_500_F_A.pdf (355.4 kB)
Etikett_Pichler_LG_500_F_B.pdf (355.4 kB)
Etikett_Pichler_LG_500_P_A+.pdf (355.5 kB)
Etikett_Pichler_LG_500_P_A.pdf (355.5 kB)
Etikett_Pichler_LG_500_PF_A.pdf (355.5 kB)
Etikett_Pichler_LG_500_PF_B.pdf (355.5 kB)
Passivhouse certifcate
2017_j-pichler-gesellschaft-mbh_lg-150-af_0800vs03_en.pdf (142.5 kB)
j-pichler-gesellschaft-mbh_lg-150-a_0745vs03_en.pdf (142.7 kB)
j-pichler-gesellschaft-mbh_lg-350-fv_1330vs03_en.pdf (142.4 kB)
j-pichler-gesellschaft-mbh_lg-350-v_1331vs03_en.pdf (142.8 kB)
j-pichler-gesellschaft-mbh_lg-450-fv_1332vs03_en.pdf (142.4 kB)
j-pichler-gesellschaft-mbh_lg-450-v_1333vs03_en.pdf (142.8 kB)
j-pichler-gesellschaft-mbh_lg-500-system-ventech_0306vs03_en.pdf (142.8 kB)
Instructions for users
08LG150_InstructionsFilterExchange.pdf (173.2 kB)
08LG150.LG250A_InstructionsControlUnit.pdf (164.3 kB)
08LG180.LG250_InstructionsControlUnit.pdf (360.7 kB)
08LG250_InstructionsFilterExchange.pdf (148.8 kB)
08LG250A_InstructionsFilterExchange.pdf (182.2 kB)
08LG350.LG450_InstructionsControlUnit.pdf (144.1 kB)
08LG350.LG450_InstructionsFilterExchange.pdf (135.9 kB)
CAD- & BIM-Data
08LG150AWLV.dwg (368.7 kB)
08LG150AWLV.rfa (1.3 MB)
08LG150AWLV.stp (3.3 MB)
08LG150AWRV.dwg (438.8 kB)
08LG150AWRV.rfa (1.3 MB)
08LG150AWRV.stp (3.3 MB)
08LG350LV.DWG (395.0 kB)
08LG350RV.DWG (391.8 kB)
08LG350RV.stp (4.1 MB)
08LG350LV.stp (4.1 MB)
08LG450LV.DWG (438.2 kB)
08LG450RV.DWG (362.5 kB)
08LG450LV.stp (4.1 MB)
08LG450RV.stp (4.1 MB)
08LG500PLV.dwg (336.8 kB)
08LG500PLV.rfa (1.5 MB)
08LG500PLV.stp (4.2 MB)
08LG500PRV.dwg (334.3 kB)
08LG500PRV.rfa (1.6 MB)
08LG500PRV.stp (4.3 MB)